Outbreak of Nontuberculous Mycobacteria Joint Prosthesis Infections, Oregon, USA, 2010–2016

Authors/contributors
Abstract
We investigated a cluster of Mycobacterium fortuitum and M. goodii prosthetic joint surgical site infections occurring during 2010–2014. Cases were defined as culture-positive nontuberculous mycobacteria surgical site infections that had occurred within 1 year of joint replacement surgery performed on or after October 1, 2010. We identified 9 cases by case finding, chart review, interviews, surgical observations, matched case–control study, pulsed-field gel electrophoresis of isolates, and environmental investigation; 6 cases were diagnosed >90 days after surgery. Cases were associated with a surgical instrument vendor representative being in the operating room during surgery; other potential sources were ruled out. A tenth case occurred during 2016. This cluster of infections associated with a vendor reinforces that all personnel entering the operating suite should follow infection control guidelines; samples for mycobacterial culture should be collected early; and postoperative surveillance for <90 days can miss surgical site infections caused by slow-growing organisms requiring specialized cultures, like mycobacteria.
Publication
Emerging Infectious Diseases
Date
05/2019
Citation
1.
Buser GL, Laidler MR, Cassidy PM, Moulton-Meissner H, Beldavs ZG, Cieslak PR. Outbreak of Nontuberculous Mycobacteria Joint Prosthesis Infections, Oregon, USA, 2010–2016. Emerg Infect Dis. 2019;25(5):849-855.